{"id":748,"date":"2021-09-26T17:31:34","date_gmt":"2021-09-26T17:31:34","guid":{"rendered":"https:\/\/science.utm.my\/physics\/?page_id=748"},"modified":"2021-09-27T16:56:06","modified_gmt":"2021-09-27T16:56:06","slug":"four-point-probe","status":"publish","type":"page","link":"https:\/\/science.utm.my\/physics\/four-point-probe\/","title":{"rendered":"FOUR POINT PROBE SET UP WITH SOLAR CELL MEASUREMENT"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;section&#8221; _builder_version=&#8221;3.22&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_row admin_label=&#8221;row&#8221; _builder_version=&#8221;4.10.8&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; custom_margin=&#8221;30px||||false|false&#8221; sticky_enabled=&#8221;0&#8243;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text _builder_version=&#8221;4.10.8&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h1>Four Point Probe with Solar Test System<\/h1>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/science.utm.my\/physics\/wp-content\/uploads\/sites\/593\/2021\/09\/FOUR-POINT-PROBE-WITH-SOLAR-TEST-SYSTEM-scaled.jpg&#8221; title_text=&#8221;FOUR POINT PROBE WITH SOLAR TEST SYSTEM&#8221; _builder_version=&#8221;4.10.8&#8243; _module_preset=&#8221;default&#8221; width=&#8221;63%&#8221; module_alignment=&#8221;center&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Text&#8221; _builder_version=&#8221;3.27.4&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; global_colors_info=&#8221;{}&#8221;]&nbsp;<\/p>\n<p><b>Brand-Model<br \/>\n<\/b><span style=\"font-weight: 400;\">Ossila, Four Point Probe, Solar Cell I-V Test System.<\/span><\/p>\n<p><b>Descriptions<br \/>\n<\/b><span style=\"font-weight: 400;\">Ossila&#8217;s Four-Point Probe System is an easy-to-use tool for the rapid measurement of sheet resistance, resistivity, and conductivity of materials. Ossila&#8217;s Solar Cell I-V System is a low-cost solution for reliable characterisation of photovoltaic devices.<\/span><\/p>\n<p>&nbsp;<\/p>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><strong>Four-Point Probe<\/strong><\/td>\n<td><strong>Solar Cell I-V System<\/strong><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Voltage range: \u00b1100 \u03bcV to \u00b110 V<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Current range: \u00b11 \u03bcA to \u00b1150 mA<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Sheet resistance range: <\/span> <span style=\"font-weight: 400;\">100 m\u03a9\/\u25a1 to 10 M\u03a9\/\u25a1 (ohms per square)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Voltage Source:<\/span> <span style=\"font-weight: 400;\">\u00b1333 \u03bcV to \u00b110 V<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Current Measurement:<\/span> <span style=\"font-weight: 400;\">10 nA to 150 mA<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Substrate Size:<\/span> <span style=\"font-weight: 400;\">20 mm x 15 mm or 25 mm x 25 mm<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.10.8&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.10.8&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Four Point Probe with Solar Test System&nbsp; Brand-Model Ossila, Four Point Probe, Solar Cell I-V Test System. Descriptions Ossila&#8217;s Four-Point Probe System is an easy-to-use tool for the rapid measurement of sheet resistance, resistivity, and conductivity of materials. Ossila&#8217;s Solar Cell I-V System is a low-cost solution for reliable characterisation of photovoltaic devices. &nbsp; Four-Point [&hellip;]<\/p>\n","protected":false},"author":273,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"&nbsp;\r\n\r\n<b>Brand-Model\r\n<\/b><span style=\"font-weight: 400;\">Ossila, Four Point Probe, Solar Cell I-V Test System.<\/span>\r\n\r\n<b>Descriptions\r\n<\/b><span style=\"font-weight: 400;\">Ossila's Four-Point Probe System is an easy-to-use tool for the rapid measurement of sheet resistance, resistivity, and conductivity of materials. Ossila's Solar Cell I-V System is a low-cost solution for reliable characterisation of photovoltaic devices.<\/span>\r\n\r\n&nbsp;\r\n<table border=\"1\">\r\n<tbody>\r\n<tr>\r\n<td><strong>Four-Point Probe<\/strong><\/td>\r\n<td><strong>Solar Cell I-V System<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"font-weight: 400;\">Voltage range: \u00b1100 \u03bcV to \u00b110 V<\/span>\r\n\r\n<span style=\"font-weight: 400;\">Current range: \u00b11 \u03bcA to \u00b1150 mA<\/span>\r\n\r\n<span style=\"font-weight: 400;\">Sheet resistance range: <\/span> <span style=\"font-weight: 400;\">100 m\u03a9\/\u25a1 to 10 M\u03a9\/\u25a1 (ohms per square)<\/span><\/td>\r\n<td><span style=\"font-weight: 400;\">Voltage Source:<\/span> <span style=\"font-weight: 400;\">\u00b1333 \u03bcV to \u00b110 V<\/span>\r\n\r\n<span style=\"font-weight: 400;\">Current Measurement:<\/span> <span style=\"font-weight: 400;\">10 nA to 150 mA<\/span>\r\n\r\n<span style=\"font-weight: 400;\">Substrate Size:<\/span> <span style=\"font-weight: 400;\">20 mm x 15 mm or 25 mm x 25 mm<\/span><\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>","_et_gb_content_width":"","footnotes":""},"class_list":["post-748","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/science.utm.my\/physics\/wp-json\/wp\/v2\/pages\/748","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/science.utm.my\/physics\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/science.utm.my\/physics\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/science.utm.my\/physics\/wp-json\/wp\/v2\/users\/273"}],"replies":[{"embeddable":true,"href":"https:\/\/science.utm.my\/physics\/wp-json\/wp\/v2\/comments?post=748"}],"version-history":[{"count":0,"href":"https:\/\/science.utm.my\/physics\/wp-json\/wp\/v2\/pages\/748\/revisions"}],"wp:attachment":[{"href":"https:\/\/science.utm.my\/physics\/wp-json\/wp\/v2\/media?parent=748"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}